Title: Static and Dynamic Analysis of a Piping System
Authors: Patel, Ketan H.
Keywords: Mechanical 2004
Project Report 2004
Mechanical Project Report
Project Report
04MME
04MME009
CAD/CAM
CAD/CAM 2004
Issue Date: 1-Jun-2006
Publisher: Institute of Technology
Series/Report no.: 04MME009
Abstract: This project work includes static and fluid induced vibration analysis, for a given piping system. Model was created as per actual configuration for resonance frequency and water hammer induced vibration analysis. The natural frequencies, static, thermal and dynamic stresses of the piping system were obtained in different 34 applied load cases. The static analysis demonstrates that the wrong boundary condition at one support location increases thermal stress and also responsible for higher moment then allowable at nozzle shell junction. Actual calculated equipment stiffness value makes this nozzle moment safer side but it is not recommended solution as design must sustained the stresses in the worst conditions. The effects of supports were analyzed during the thermal analysis in different temperature range, to obtain maximum thermal stresses. As a result none of the segments were close to the actual thermal and allowable stresses ratio of 1.0 so it was acceptable. In the vibration resonance analysis the first, second and third natural frequency of system was found at 3.70 Hz, 4.37 Hz and 4.98 Hz with its corresponding mode shapes and it was compared with fluid’s excitation frequency to find out resonance region. As a result middle segment of model was found in resonance condition at a maximum flow rate of 110.66 feet3/sec. In the water hammer analysis failure prediction was found and the time of valve closing and opening were obtained as a parameter to control the crest of wave pressure. The result shows that with adequate time of valve operation, the wave crest will not reach to the pressure of failure. The pressure reducer may be kept before the valve in order to reduce the impact of this traveling wave. Redesign and relocation of trunion support also decreases the dynamic stresses as well as nozzle moment. Hence in this project work, the possible causes of nozzle failure were identified and appropriate suggestions were given.
URI: http://hdl.handle.net/123456789/103
Appears in Collections:Dissertation, ME (CAD/CAM)

Files in This Item:
File Description SizeFormat 
04MME009.pdf04MME0092.01 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.