Please use this identifier to cite or link to this item: http://10.1.7.192:80/jspui/handle/123456789/10606
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAdesara, Ankit Mukeshbhai-
dc.date.accessioned2022-02-08T10:29:06Z-
dc.date.available2022-02-08T10:29:06Z-
dc.date.issued2021-06-
dc.identifier.urihttp://10.1.7.192:80/jspui/handle/123456789/10606-
dc.description.abstractThe continuous real-time monitoring of diverse physical parameters using bio-signals like ECG and EEG requires the bio-medical sensors for capturing those signals. Such a sensor consists of an analog front-end unit for which the operational transconductance amplifier (OTA) is an essential block. Along with noise and power, the parameters like CMRR, input impedance, DC offset and output ripple must be taken into consideration while designing as they equally affect the overall performance of amplifier. In this work, the novel chopper-stabilized bio-potential amplifier is proposed. The chopper-stabilization method is used, by judiciously selected chopping frequency, to reduce the DC electrode offset and flicker noise. Further, the operational transconductance amplifier (OTA) is equipped with a additional circuit in form of forward path to enhance the input impedance without consuming extra power. In addition to this, the ripple reduction technique is employed at the output branch of the operational transconductance amplifier. The designed amplifier can be used for various applications like portable devices, wearable electronics and health care devices The major challenge while designing was to maintain the balance in performance in terms of noise and power due to the existence of a trade-off between them. The specifications have been carefully chosen after detailed study of ECG and EEG recording systems for the bio-potential amplifier as it processes very low amplitude and frequency bio-signals, not only that the Layout design was very crucial due to issues of matching of various devices as it also affects overall circuit performance The designed amplifier consumes 5.5 µW power with the mid-band gain of 40 dB. The passband for the designed amplifier is 0.1 Hz to 1 KHz. The input impedance is likewise boosted with the proposed method up to 200 MΩ. The noise is 42 nV/√Hz with CMRR of 82 dB. All the pre- and post-layout simulations are carried out using 180nm technology node.en_US
dc.publisherInstitute of Technologyen_US
dc.relation.ispartofseriesTT000100;-
dc.subjectThesesen_US
dc.subjectEC Thesesen_US
dc.subjectTheses ECen_US
dc.subjectDr Amisha Naiken_US
dc.subject14EXTPHDE131en_US
dc.subjectTT000100en_US
dc.subjectTheses ITen_US
dc.subjectITFEC007en_US
dc.titleDesign and Implementation of a Low-noise Low-power Bio-potential Amplifier For Biomedical Applicationsen_US
dc.typeThesisen_US
Appears in Collections:Ph.D. Research Reports

Files in This Item:
File Description SizeFormat 
TT000100.pdfTT00010040.48 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.