dc.description.abstractIn modern world, heat pipes have shown their considerable importance in cooling of electronic circuits, super computer systems, aerospace thermal management, nuclear reactors and so on. Conventional heat pipes are used to cool single heat source in an electronic circuit. Nowadays, heat pipes are developed which can provide cooling to multiple heat sources due to space constrain in aerospace and electronic systems. Multi-branch heat pipe is a ‘T’ shaped heat pipe with three branches in which there are two evaporator sections and one condenser section. Axially grooved multi-branch heat pipe (AGMBHP) is experimentally investigated for various parameters in the present work. Experimental investigation is carried out for optimum filling ratio 150%, and results are presented in terms of thermal resistance, dynamic characteristics, temperature distribution, heat transfer co-efficient and cooling water flow rate. In horizontal orientation, AGMBHP is capable to transfer 240 W heat load with minimum total thermal resistance of 0.192 °C/W at 150% filling ratio. Performance of heat pipe is further investigated for gravity assisted orientation (GAO), anti-gravity orientation (AGO) and compound orientation (CO) for heat load range of 0-200 W or up to dry-out condition. The heat transfer co-efficient are found and compared for different orientations which suggests horizontal orientation (HO) to be optimum. AGMBHP is compared with MBTHP in terms of thermal resistance and effective thermal conductivity. A C programming code is generated to calculate overallheat transfer co-efficient and LMTD for water cooled condenser of AGMBHP.en_US
dc.publisherInstitute of Technologyen_US
dc.relation.ispartofseries20MMET10;-
dc.subjectMechanical 2020en_US
dc.subjectProject Report 2020en_US
dc.subjectMechanical Project Reporten_US
dc.subjectProject Reporten_US
dc.subject20MMETen_US
dc.subjectThermalen_US
dc.subject20MMET10en_US
dc.subjectThermal 2020en_US
dc.subjectAxially Grooveden_US
dc.subjectMulti-branch Heat Pipeen_US
dc.subjectGravity Assisted Orientationen_US
dc.subjectAgainst Gravity Orientationen_US
dc.subjectHorizontal Orientationen_US
dc.subjectCompound Orientationen_US
dc.titleExperimental Investigation on Axially Grooved Multi-branch Heat Pipeen_US
dc.typeDissertationen_US
Appears in Collections:Dissertation, ME (Thermal)

Files in This Item:
File Description SizeFormat 
20MMET10.pdf20MMET1033.39 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.