Please use this identifier to cite or link to this item: http://10.1.7.192:80/jspui/handle/123456789/1264
Title: Generation of Parabolic Trajectories for Current Error Space Phasor similar to an SVPWM Controller for Control of Switching Frequency Variation in Current Hysteresis PWM Controlled IM Drives
Authors: Tekwani, P. N.
Kanchan, R. S.
L. Sanjay
Gopakumar, K.
Keywords: Electrical Faculty Paper
Faculty Paper
ITFEE003
Issue Date: 2006
Publisher: IEEE
Citation: International Conference on Industrial Technology IEEE, 2006 ICIT 2006.
Abstract: Switching frequency variation over a fundamental period is a major problem associated with hysteresis controller based VSI fed IM drives. This paper describes a novel concept of generating parabolic trajectories for current error space phasor for controlling the switching frequency variation in the hysteresis controller based two-level inverter fed IM drives. A generalized algorithm is developed to determine unique set of parabolic trajectories for different speeds of operation for any given IM load. Proposed hysteresis controller provides the switching frequency spectrum of inverter output voltage, similar to that of the constant switching frequency VC-SVPWM based IM drive. The scheme is extensively simulated and experimentally verified on a 3.7 kW IM drive for steady state and transient performance.
Description: Page No. 2414-2419
URI: http://hdl.handle.net/123456789/1264
ISBN: 1-4244-0726-5
Appears in Collections:Faculty Papers, EE

Files in This Item:
File Description SizeFormat 
ITFEE003-8.pdfITFEE003-81.28 MBAdobe PDFThumbnail
View/Open