Please use this identifier to cite or link to this item:
http://10.1.7.192:80/jspui/handle/123456789/5986
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Joshi, Lovekumar | - |
dc.date.accessioned | 2015-08-12T07:38:56Z | - |
dc.date.available | 2015-08-12T07:38:56Z | - |
dc.date.issued | 2015-06-01 | - |
dc.identifier.uri | http://hdl.handle.net/123456789/5986 | - |
dc.description.abstract | Electrical equipments generate heat through I2R loss at higher current within a given volume that results in temperature rise. So during the design procedure for large current electrical equipment thermal analysis can predict approximate temperature rise in various locations. This project presented a development of new prototype for various ratings of 12 kV indoor VCB panel on which FE analysis is carried out. Here an equivalent model along with all current carrying parts and contacts are designed for analysis purpose. So ANSYS Thermal-Electric coupled field analysis tool is used to analyze the temperature rise. On this newly developed model temperature rise test shall be carried out experimentally. Furthermore it demonstrates how expertise analysis is carried throughout the development phase which are critical to the success of a cost, size and performance optimized switchgear design. The achievement in this project provide an precise and effective method for simulation of temperature rise of different parts and its contacts, which could be applied on contacts of different materials which gives good reference for reliability verification and optimum design of panel. Hence, on the basis of these results, prototype shall be developed. The results of temperature rise test with a prototype model showed good agreement with the analysis results. | en_US |
dc.publisher | Institute of Technology | en_US |
dc.relation.ispartofseries | 13MEEE04; | - |
dc.subject | Electrical 2013 | en_US |
dc.subject | Project Report 2013 | en_US |
dc.subject | Electrical Project Report | en_US |
dc.subject | Project Report | en_US |
dc.subject | 13MEE | en_US |
dc.subject | 13MEEE | en_US |
dc.subject | 13MEEE04 | en_US |
dc.subject | EPS | en_US |
dc.subject | EPS 2013 | en_US |
dc.subject | EE (EPS) | en_US |
dc.subject | Electrical Power Systems | en_US |
dc.title | Study and Analysis of Thermal Characteristics of Medium Voltage Switchgear at rated Current | en_US |
dc.type | Dissertation | en_US |
Appears in Collections: | Dissertation, EE (EPS) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
13MEEE04.pdf | 13MEEE04 | 10.71 MB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.