Please use this identifier to cite or link to this item: http://10.1.7.192:80/jspui/handle/123456789/8728
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJoshi, Devang-
dc.date.accessioned2019-08-19T08:55:03Z-
dc.date.available2019-08-19T08:55:03Z-
dc.date.issued2017-06-01-
dc.identifier.urihttp://10.1.7.192:80/jspui/handle/123456789/8728-
dc.description.abstractThe Helium Refrigerator/Liquefier (HRL) plant requires the compression of helium gas for the liquefaction of helium. Considering the volumetric flow rate and pressure requirements, the oil injected screw compressors are used for the compression process. In order to avoid high heating and to increase the component life of screw compressor, oil of heavy molecule which has a high specific heat is mixed with helium before compression. Before using this compressed helium (He) gas for refrigeration, it is necessary to cool it to about room temperature and separate the oil from the mixture. For this, there are heat exchangers, bulk oil separator tanks, oil recirculation pumps, coalescers, adsorber beds, filters, valves and other instrumentation needed and this whole system is called as Compressor and Oil Removal System (CORS). An analysis of the modification work has been done related to how an air screw compressor and oil removal system can be used as helium compressor system. In the present work, investigations with analysis and optimization have been done for improvement the performance of this modified system. In the present report, a parametric study of discharge temperature, work, suction pressure, pressure ratio, inlet temperature, oil inlet temperature, oil gas mass ratio, oil intake position, etc. are carried out. Also the effects of these parameters on the volumetric efficiency, adiabatic efficiency and the specific power consumption of twin screw compressor are considered. The performance improvement of CORS is done by theoretical performance calculation so as to minimize the oil concentration in downstream side in order to avoid the damage to the high speed turbine. The coalescer test facility is designed for the removal of the oil after the compression process. Also the theoretical calculation of performance has been made in this report which gives efficiency equal to 99.9999 for a mean oil droplet of diameter 0.12µm. The performance analysis of coalescer has been carried out. The shell and tube type water cooled heat exchanger is used for cooling of the helium gas. The performance analysis of the existing shell and tube heat exchanger is undertaken. Also the theoretical design is compared with the HTRI and ASPEN softwares. The thermo-hydraulic design, optimization and analysis of the helium cooler for the new proposed plant is carried out as per the available parameters.en_US
dc.publisherInstitute of Technologyen_US
dc.relation.ispartofseries15MMET07;-
dc.subjectMechanical 2015en_US
dc.subjectProject Report 2015en_US
dc.subjectMechanical Project Reporten_US
dc.subjectProject Reporten_US
dc.subject15MMETen_US
dc.subject15MMET07en_US
dc.subjectThermalen_US
dc.subjectThermal 2015en_US
dc.subjectScrew Compressoren_US
dc.subjectCoalesceren_US
dc.subjectAdsorber Beden_US
dc.subjectShell and Tube Heat Exchangeren_US
dc.subjectCold Boxen_US
dc.subjectPressure Dropen_US
dc.titleDesign and Analysis of Oil Removal System and Helium Cooler for Conversion of Air Compressor to Helium Compressoren_US
dc.typeDissertationen_US
Appears in Collections:Dissertation, ME (Thermal)

Files in This Item:
File Description SizeFormat 
15MMET07.pdf15MMET074.98 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.