Please use this identifier to cite or link to this item: http://10.1.7.192:80/jspui/handle/123456789/3178
Title: Experimental Investigation on Double Inlet Pulse Tube Refrigerator
Authors: Shah, Hitarth V.
Shah, Balkrushna A.
Keywords: Cryocooler
Pulse Tube Refrigerators
Double Inlet Pulse Tube Refrigerator
Review
Mechanical Faculty Paper
Faculty Paper
ITFME030
NUiCONE
NUiCONE-2010
Issue Date: 9-Dec-2010
Publisher: Institute of Technology
Citation: 1st International Conference on Current Trends in Technology, NuiCONE-2010, Institute of Technology, Nirma University, December 9-11, 2010
Series/Report no.: ITFME030-5
Abstract: The absence of moving components at low temperature end gives the pulse tube refrigerator (PTR) a great leverage over other cryo-coolers like Stirling and GM refrigerators that are conventionally in use for several decades. PTR has greater reliability, no electric motors to cause electromagnetic interference, no sources of mechanical vibration in the cold head and no clearance seal between piston and cylinder. Moreover, it is a relatively low cost device with a simple yet compact design. The objectives of the present work are to understand the basic phenomena responsible for the production of cold effect with the help of simple theoretical models based on ideal behaviour of gases and to do experimental studies consist of cooling behaviour of the refrigeration system and suggesting modifications to improve the performance of the PTR.
URI: http://10.1.7.181:1900/jspui/123456789/3178
Appears in Collections:Faculty Paper, ME

Files in This Item:
File Description SizeFormat 
ITFME030-5.pdfITFME030-51.77 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.