Title: Analysis and Elimination of the Circulating Current Flow in Parallel Operation of 3 Level T-Type Grid Connected Inverters
Authors: Vanapariya, Jaydeep
Keywords: Electrical 2014
Project Report 2014
Electrical Project Report
Project Report
EE (PEMD)
Power Electronics, Machines  & Drives
14MEE
14MEEP
14MEEP29
PEMD
PEMD 2014
Issue Date: 1-Jun-2016
Publisher: Institute of Technology
Series/Report no.: 14MEEP29;
Abstract: An inverter is a device which converts the dc power to the ac power to supply it to various ac loads. High power with lower voltage and current ripple can only be catered by multilevel inverters. Multilevel inverter has advantage of lesser har- monics at output side, ability to control reactive power ow, quality output voltage, limitation of device stress, these prose cannot be su ced by two-level inverters so that three-level inverters are having market interest in recent era. Three-level T-type inverter has positive aspects of Two-level inverter such as reduced no of devices, low conduction losses, simple operation with the advantage of Three-level inverters such as low switching losses and superior output quality. Sometimes application needs higher power which cannot be supplied by single inverter unit, there in need of par- allel operation of inverter rises. A zero sequence circulating current(ZSCC) ows between inverters due to their switching state difference mainly which causes cur- rent discrepancy, current waveform distortion, power loss and heating of devices. In this project,the ZSCC paths in parallel network of 3LT2I are analysed, and based on that, various ZSCC inhibition techniques(Carrier synchronization, Zdq control, DC bus Mid point sharing and filter modification) are simulated in Psim simulation tool. Triangular carriers are generated separately for run time modification of various parameters and device characteristics are feeded to emulate the behaviour of actual IGBT. It is found out that Triangular(Carrier) synchronization method reduces the ZSCC current ow between inverters in present system. Experimental results also verifies the stated method with reduction of ZSCC ow from 64A to 1A at 10% of current reference.
URI: http://hdl.handle.net/123456789/6842
Appears in Collections:Dissertation, EE (PEMD)

Files in This Item:
File Description SizeFormat 
14MEEP29.pdf14MEEP299.04 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.